Forced ventilation system in a vulture house. Features of ventilation in houses made of sip panels. Troubleshooting

When building a house from SIP panels, you need to think about ventilation. SIP panel is a modern building material that has high strength and low weight. Manufacturers of such facilities offer consumers ready-made solutions with a well-thought-out ventilation system. Such designs are guaranteed for 5-10 years.

The air permeability of a well-built house made of SIP panels is significantly less than other types of buildings, so special attention must be paid to the ventilation system.

Features of ventilation of a house made of SIP panels

The air in a house made from SIP panels is constantly polluted for reasons such as:

  • evaporation from cooking;
  • combustion of oxygen by heating units;
  • dust;
  • microbes;
  • pet hair.

Ventilation of a house using SIP requires the installation of standard hoods. Experts recommend that if condensation forms on entrance doors install a second door leaf made of wood. Otherwise, a dressing room with an area of ​​1.5-2 sq.m. is built.

Previously, air masses entered the room through poorly closed windows. If the house was made of clay, then a special hole was made under the ceiling, which ensured a regular flow of air masses. The chimney was of great importance.

When choosing a ventilation system for a house made of SIP panels, the fact that the factory-made building material is made without clearance and is fitted together as tightly as possible is taken into account.

If the house is built from natural materials, then its walls are provided with minimal ventilation. Modern panels eliminate the possibility of minimal uncontrolled air flows.

Return to contents

Basic methods of ventilation

The top layer of the house is presented in the form facing material, which protects the interior space from environmental influences, while retaining heat inside the building. Ventilation in any home is arranged according to a certain scheme. Calculations are made in advance.

Experts recommend equipping the window frames and walls of the house with supply ducts. Installation work must be carried out when installing the window frame and walls. This technology ensures air penetration only inside the house. To remove used oxygen from the building, you will need to install a special system and install ventilation shafts with small fans. The shafts lead to the bathroom and storage room.

To ensure good ventilation of a house with an area of ​​200 square meters. m will need to make 7 similar mines. In order not to make 7 holes in the roof of the building, it is recommended to combine the channels into one shaft, connecting the system to 1 powerful fan. The disadvantage of this technology is the removal of recycled air and heat from the house.

The most practical method of arranging ventilation is heat recovery. This technology reduces heat loss to a minimum, ensuring a constant flow of air into the building. Some experts recommend installing forced-air fan heaters in houses made of SIP panels, designed to remove used air outside, collect and return clean air to the room. Such units heat the air to room temperature, preventing the room from cooling down and significantly saving money on heating.

One of the disadvantages of houses made of SIP panels is that the so-called thermos effect is created inside them. That is, there is no natural air exchange between the premises and the street in such structures. To make living in such a building comfortable in the future, a ventilation system must be installed during its construction. At the same time, when installing such a network, you must strictly adhere to all the required standards.

What types of ventilation can be installed

The design of a utility system of this type when designing houses from SIP panels is usually chosen depending on the area of ​​the latter. In small residential buildings, a natural ventilation system is most often installed. In houses made of large-area SIP panels, forced communications of this type are installed.

Most often, ventilation systems are installed in such buildings at the stage of their construction. In some cases, the construction company even gives owners a guarantee of the effective operation of such a network for several years. But, of course, ventilation in such frames can be installed after their construction. This is, for example, what is often done when constructing small-area SIP buildings.

Natural ventilation system in SIP houses

These are installed in residential buildings of this type using approximately the same methods as in any others. But since houses of this type are absolutely airtight, all required technologies and standards in this case are observed with maximum accuracy.

In houses built in a traditional way, using ordinary materials, exhaust air is removed from the premises through an exhaust riser or grilles. Its influx is carried out through cracks in the structures of the building itself.

For a house made of SIP panels, approximately the same technique for arranging ventilation is used. But in this case it has some of its own characteristics. The very technology of constructing such buildings completely eliminates the presence of any gaps in their structures. Therefore, networks with natural air circulation in SIP houses are equipped using additional devices.

Natural ventilation equipment: valves

In order for air to freely flow into and out of rooms, special supply valves are installed in the walls of SIP buildings. The following elements can be installed:

    under the window sills;

    directly in window frames;

    next to the windows in the wall.

Moreover, most often in SIP houses they are installed using the first technology. If such an element is mounted under a window sill, the street air entering the premises through it will be winter time will be heated by a heating radiator. In addition, such an installation usually provides better draft through the valve.

A feature of devices of this type is, among other things, that their design includes an element that allows you to control the volume of air coming from the street.

Hood

When arranging natural ventilation in houses made of SIP panels, of course, it is necessary to provide for the removal of exhaust air. For this purpose, exhaust grilles can be installed in bathrooms and kitchens of small SIP buildings. Such elements are installed under the ceiling of these rooms. At the same time, they must be supplemented with check valves so that air from the street does not penetrate through them into the bathroom and kitchen.

Equipment installation technology

Holes are pre-drilled under and houses made of SIP panels. Next, pipes are inserted into them. The “stuffing” of valves and hoods is, in turn, mounted into these elements.

Very often, in houses made of SIP panels, as in any other, ground floor. Of course, the owners of such a building should definitely ensure high-quality ventilation of this room as well. Basement ventilation in houses made of SIP panels is installed in the same way as in residential premises. That is, when pouring the foundation, vents are left in the tape, and then supply valves and exhaust grilles are inserted into them.

Types of artificial ventilation

Such systems in houses from SIP panels are also assembled quite often. At the same time, an artificial ventilation network can be installed in buildings of this type:

    exhaust;

    supply and exhaust.

The first type of networks is assembled using the same equipment as natural ventilation. That is, in this case, supply valves and grilles are also installed. However, when assembling such systems, fans are additionally inserted into the exhaust openings in bathrooms and kitchens. The use of such equipment allows you to speed up air exchange in a house made of SIP panels and make its microclimate more pleasant.

Supply and exhaust ventilation systems in houses made of SIP panels are usually installed only if they have a very large area. When installing such networks, among other things, air ducts are also installed in the building. A supply and exhaust unit is also installed in the house.

Installation of artificial ventilation with air ducts: project

Setting up such a network is technologically quite complex. In principle, you can install a supply and exhaust ventilation system, including in a house made from SIP panels, with your own hands. However, the owners of country residential buildings usually entrust the development of such a network project to specialists.

This matter is actually very complex and responsible. If the air ducts are laid incorrectly, the ventilation of a private house using SIP panels will subsequently be ineffective. In addition, the owners of such a residential building may significantly increase their heating costs in winter.

SNiP requirements

When drawing up a project for supply and exhaust ventilation of a house made of SIP panels, specialists, among other things, must take into account SNiP standards. Ultimately engineering Communication of this type in such a building must be laid so that they provide air exchange:

    for residential premises - 3 m 3 / h per 1 m 2 area;

    for kitchens - 90 m 3 / h when using a gas stove and 60 m 3 / h when using an electric one;

    for separate baths and toilets - 25 m 3 / h;

    for a combined bathroom - 50 m 3 / h.

In cold regions, if in winter the outside air temperature drops below -40 °C, the ventilation network in houses must be supplemented with heating equipment.

Supply and exhaust network assembly technology

Install such a ventilation system in the house with your own hands, if available. finished project it will be relatively easy. When assembling networks of this type, at the first stage, holes are also usually drilled in the walls, through which fresh air will subsequently enter the building. Further:

    pipes are inserted into the drilled holes and covered from the street side with gratings;

    from the room side, supply air ducts are connected to the branch pipes, after which they are laid to the installation site of the air handling unit;

    Hoses are led from the supply air ducts into the rooms;

    an exhaust air duct is laid through the ceilings and slopes of the house with a connection to the roof;

    hoses from the premises are laid to the exhaust air duct;

    the air handling unit is being installed in place;

    The main supply and exhaust lines are connected to the installation.

The main equipment responsible for air circulation in the premises of a house made from SIP panels is usually installed in the attic. Supply hoses are introduced into rooms in pipes through the walls. The ventilation of a house made of SIP panels should be arranged so that the latter enter the premises along the bottom of the enclosing structures.

Extracting sleeves are also introduced into the premises in exactly the same way. But in this case, holes in the walls are drilled at the top. At the final stage, the air duct outlets in the rooms are covered with decorative grilles.

If all the required technologies are strictly followed, the ventilation system in the house from SIP panels can be equipped with a truly effective one. When installing such communications, experts, among other things, advise adhering to the following recommendations:

    It is better to choose an air handling unit for such a house supplemented by a recuperator;

    It is worth buying plastic pipes for supply valves and grilles.

When using a recuperator, the air coming from the street will be heated by the exhaust air. And this, in turn, will save on heating the SIP house.

Metal pipes are not used when installing supply valves and hoods in residential buildings due to the fact that air passing through them can produce strong noise. Such devices can be used, for example, only in utility rooms or on basement floors.

From the author: good afternoon, dear readers! One of the basic trends in current suburban construction is energy saving. To achieve the desired effect, the most advanced technologies are used - innovative Construction Materials, thoughtful location of the house on the site, metal-plastic windows, careful insulation of the roof and facade. Canadian technology for building houses from SIP panels has successfully proven its competitiveness.

However, excellent thermal insulation of a house implies the need for a well-thought-out ventilation system. Some experts are confident that ventilation in a house made of SIP panels can be limited to natural channels throughout the house and a forced exhaust system in places of high humidity (in the bathroom and kitchen). Is it really? Let's try to figure it out!

Need for ventilation

“Dream House” is a cozy space, protected from the influence of negative external factors. Ideally, it should be practically airtight. This criterion primarily applies to a Canadian energy-efficient home. However, a person cannot live in a sterile space, which is akin to an operating room. Naturally, air pollution occurs in the process of life. Thus, in a private home it is simply necessary to organize the process of exchanging “used” air for fresh air in order to avoid illnesses and allergic manifestations.

The main causes of air pollution in residential buildings:

  • household and electrical appliances “eat up” oxygen;
  • steam is generated when cooking;
  • detergents and washing powders provoke the appearance of harmful fumes;
  • dust;
  • pet fur.

These reasons are quite enough to concern ourselves with the problem of air purification, especially when it comes to residential buildings made of SIP panels. Without a well-thought-out air exchange system, including forced ventilation, such a house turns into a stuffy box. If you simply open the windows wide open, letting in oxygen from the street, then the cost of heating your home will skyrocket.

To avoid such a scenario, you need to take care of the regular supply of fresh air into the room, that is, consider a forced oxygen flow scheme and an exhaust system.

Types of ventilation in a “Canadian” house

When choosing the type of ventilation, you should focus on your budget. For example, this could be a democratic system of several adaptive supply valves in windows or walls, which ensures air flow. Forced exhaust The polluted air then passes through the roof or wall. A more expensive option is ventilation air handling units with recovery.

Let us consider in detail all the options for ventilation of a house made from SIP panels along with their features.

Natural ventilation

Natural ventilation involves the entry of air into the room without additional equipment. In houses built according to Canadian technology, it is recommended to use special supply valves built into walls and windows - this will provide additional air circulation. It is quite possible that the owners of a house made of SIP panels will still have to take care of forced ventilation, since the “natural ventilation” scheme may be ineffective.

In case of insufficient ventilation, it is naturally recommended to install a hood from the bathroom, toilet, or kitchen. This will prevent unpleasant odors from traveling throughout the house. Vapors and unwanted odors will be immediately directed into the exhaust air ducts. This type of ventilation is usually called static.

If you have a separate bathroom, then there are three air ducts in the house, if it is a combined one, then two. How to arrange ventilation outlets on the roof in such cases? You should not make separate holes for each channel; it is better to combine them into a common pipe immediately before exiting to the roof.

When the hood is ready, it is important to take care of the flow of fresh air into the living spaces. There are several effective ventilation system designs . Air can constantly flow into the house as follows:

  • by gravity, we are talking about the mode of micro-ventilation of windows;
  • through supply valves (in walls, windows);
  • through a separate supply device. Options are available with air filtration and heating, as well as air distribution over several rooms.

Features of static ventilation

Before proceeding with the installation of supply valves, we recommend paying attention to some important nuances of organizing effective home ventilation from SIP panels:

  • Considering that such houses are rarely built above two floors, it is important to take care of mechanical exhaust air exhaust. Otherwise, the draft in the ventilation system will simply not be enough;
  • take care of the noise insulation of the exhaust fan, since sound in houses made of SIP panels spreads instantly;
  • do not use for ventilation plastic pipes, as they accumulate static electricity and attract dust. The best option- galvanized steel structure;
  • it is impossible to lay vertical air ducts in walls made of SIP panels, so the latter are installed open and then decorated or covered with panels;
  • in small rooms you need to carefully choose the location for installing ventilation valves. Remember that the cold air that enters the room from the outside needs to be mixed with warm air. Therefore, if you install the valve in close proximity to the sleeping place, you will feel discomfort in winter.

Forced ventilation (mechanical)

This ventilation system uses special valves that deliver clean air into the room. In such cases, the hood should be made autonomous. Today, several options for mechanical ventilation are used to ventilate houses made of SIP panels:

  • supply;
  • air supply with VAV function;
  • supply and exhaust;
  • supply and exhaust with heat recovery.

This video is dedicated to the supply and exhaust ventilation system:

What is the difference between these ventilation systems? In short, the above-mentioned ventilation differs in basic design elements, but their operating scheme is the same - injection of fresh air and removal of polluted air using exhaust ventilation ducts.

Supply ventilation is considered one of the most economical. Clean air is forced into the home and through the ventilation system and displaces stale air through ducts in the bathrooms and kitchen.

In any home, the ventilation system is designed not only to provide air convection, but also to remove moisture that accumulates inside the room. This increases the thermal resistance of the walls and extends their service life. Ventilation is provided at the design stage of the house and installed during its construction or installed in already erected buildings.

Types of ventilation for a frame house

Ventilation in a house made of SIP panels comes in three types:

  • natural;
  • forced;
  • combined.

Air exchange method panel house determined depending on the area of ​​the premises, the number of residents and the budget of the owners. Most manufacturers frame houses they make the structure of the building in such a way that the owner can install one or another ventilation system after construction.

Most air exchange systems are based on the direct-flow principle. It provides for the removal of superheated air through exhaust ducts. However, along with it, most of the heat is removed from the room, which makes such a system energy-consuming.

To reduce heat loss to a minimum, it is necessary to install recuperators in panel-type houses. Heat fans remove exhaust air from the room, mix it with clean air, and heat it to room temperature through the process of convection. Then they are returned back to the room. This method of ventilation significantly reduces the cost of subsequent heating of the house.

Features of natural air exchange in panel houses

Natural ventilation in houses made of SIP panels involves the entry of fresh air through cracks and gaps formed due to loose fixation of windows, doors, interfloor ceilings or through exhaust ducts. However, a house of this type is different in that the structure does not provide for the presence of cracks, holes, etc. SIP panels are completely airtight.

The device of natural ventilation requires the presence of exhaust ducts in the bathrooms and kitchen, which exit through the roof. To do this, install pipes made of plastic or galvanized steel. The first material is cheaper, but it strongly attracts dust, which reduces the draft of the channel. Therefore, galvanized steel pipes are often chosen.

To ensure the supply of fresh air and increase draft in walls or windows, supply valves are installed. The best location is considered to be a hole above the heating boiler, since cold air entering the room is heated by the operation of the device. The valve should be installed in such a way that air circulates inside the building towards the kitchen and bathrooms.

For supply valves, pipes from:

  • plastic;
  • asbestos cement.

Experts recommend choosing products made from asbestos cement. It is not advisable to install metal pipes, since they reduce the thermal insulation of the walls and increase the noise load. The disadvantage of valves is the violation of the integrity of the sound insulation of the walls. If the building is located in a noisy area, supply valves should be abandoned. This type of ventilation does not have high power, but you can do it yourself and it is cheaper compared to other types.

Characteristics of forced ventilation for a frame house

Forced SIP panels provide high-quality air convection. In this case, special mechanical devices with a noise-insulating housing are used. A simple option is supply ventilation, in which exhaust air is removed through channels by forcing fresh air into the room. If necessary, it is possible to supply only certain areas of the building. If not only the injection but also the removal of air occurs forcibly, this method is a supply and exhaust method.

The most expensive is ventilation with heat recovery. To save on heating costs, warm air enters the room. It warms up due to the outgoing flow. This system is suitable for houses with a large area. In small buildings, recuperation is considered overkill because the building materials used have low thermal conductivity.

The operation diagram of forced ventilation looks like this:


Description of mixed air exchange

Mixed is most often used. It allows for high-quality air exchange and air circulation inside the room. This type is less energy-consuming compared to the forced system. In this case, the air is removed from the building through ventilation ducts.

Their number and size are selected depending on the dimensions of the building. Experts recommend installing 6-8 channels for every 180-200 m². Pipes are selected from asbestos cement or PVC. Their connections form a collector for air masses.

On finished design a fan is installed. Its power will determine the thrust of the entire system. The device can be mechanical or automatic. The operation of the latter is regulated by humidity sensors, which are installed in all rooms of the building. The fan power must be calculated by specialists, since it is extremely difficult to correctly determine this parameter on your own.

Troubleshooting

You can determine the malfunction of ventilation in SIP houses if the following points are observed:

  • in some rooms or throughout the house the air is stale, heavy, there is little oxygen and it is difficult to breathe;
  • fungus forms in the kitchen and bathroom;
  • Water vapor appears on the windows.

In the first case, most likely there is insufficient fan power or weak draft if a natural type of air exchange is used. It may also be necessary to clean the ventilation ducts. In each case, you should contact specialists for help, since it is difficult to do the cleaning yourself or calculate the power correctly. If fungus forms or windows fog up, then ventilation cannot cope with removing moisture from the room.

You can install ventilation systems yourself. But design and calculations should be carried out by specialists, since without knowledge it is difficult to determine all the parameters.

Houses made of SIP panels require constant air circulation. Such buildings, as a rule, do not have more than one floor. Therefore, even the simplest devices are used for ventilation in SIP houses. The ventilation system in such buildings can be either natural or forced. In houses with complex architecture you can find combined ventilation.

Types of ventilation in houses made of SIP panels

Ventilation in a frame-type residential building is a necessity. Its arrangement should be considered at the stage of building construction. In an unventilated house, there is a high probability of bacteria and fungi appearing and structural parts and wiring rotting.

The air in a room without or with improperly equipped ventilation is polluted by the following sources:

  • pets;
  • carbon monoxide from the stove and other appliances;
  • powders and detergents;
  • human waste products (carbon dioxide, skin particles, hair, etc.);
  • mold and mildew.

All of the above factors can lead to illnesses in the household or to the destruction of the wooden parts of the building.

Design selection

Standard ventilation in a house made from SIP panels works according to the principle natural circulation. Warm air escapes through the hoods. However, along with pollution, heat leaves the room. Such systems increase heating costs and can cause the formation of unwanted condensation.

To ensure that heating resources are not spent on heating, but only on maintaining a comfortable temperature, ventilation with heat recovery is used. A standard example of such a design is waste heat installations. Fans remove stale air from the home and bring a mixture of recycled and outdoor air inside. The device allows you to save on heating due to the fact that the air entering the room is already heated.

Particular attention is paid to heat loss at home at the project creation stage. Improper ventilation can increase these indicators significantly. A recuperation system is particularly suitable for houses made of SIP panels.

Natural

Natural ventilation is a system of gaps and cracks provided by the design for normal air outflow. However, in houses made of SIP panels, such a technique is used extremely rarely. Buildings made from such material are built as tightly as possible, without any holes.

It is possible to install a natural ventilation system in houses with SIP panels. For this purpose, special mechanical valves are used for air flow. They are installed at the stage of wall construction or when finishing the building. The devices do not damage at all appearance building. Asbestos-cement or plastic pipes act as ventilation valves.

Important! Metal pipes are not suitable for construction due to high noise load and reduced thermal insulation properties of the building.

The volume of air exchange provided natural ventilation, enough for one-story houses. For large buildings it is better to use electrical installations or combined methods. The design of ventilation in a house depends on its architecture. Asbestos cement slabs are recommended for laying pipes; they reduce noise pollution.

Forced

In terms of power, the forced ventilation system is one of the best. It has one significant drawback - the complexity of installation. However, a well-designed system will last for decades.

The system works in such a way that the air released into the building's floors is cleaned and heated. It is very difficult for an untrained person to assemble such a structure. It is best to use the services of professionals.

The operating principle of such structures is as follows:

  1. The hood removes the building's recycled air from the home to the outside. The air circulates back through the supply channels.
  2. When polluted air is emitted, the indoor climate is replenished with an equal volume of clean air from outside. It enters the building through constant circulation.
  3. Due to the temperature of the air masses emitted outside, the fresh ones are heated and come inside already warm. In addition to the atmosphere of the room itself, the structural parts of the building also warm up. Thus, the heat loss of the building is significantly reduced.

The difficulty in building the system is that if you calculate the height or volume of the exhaust valves, the room will quickly cool down.

Mixed

The combined ventilation system provides constant air exchange, without high energy costs (unlike forced ventilation). The design is represented by ventilation ducts. Their cross section depends on the parameters of the house. It is standard to have about 8 channels for every 200 m2. The smaller the building, the fewer channels required. For their arrangement, plastic or asbestos cement pipes. They form a multi-level system, like a collector. An electric fan is already installed in it. The larger the building, the higher the installation power required.

In addition to electronic ones, mechanical installations are also used; they do not waste much energy, but have less power. Automatic ones are more convenient because their operation is regulated by the air condition in the room. If the humidity rises, circulation turns on. In addition to this modification, there are devices with infrared devices, but they are much more expensive than the simplest electronic ventilation.

Note! It is best to entrust the calculation of fan power to a specialist. Lack of qualifications can cost big losses.

Dangers of an incorrect ventilation system

Very often it is necessary to replace the entire ventilation if serious flaws were made in its installation. This requires a lot of resources and time. The same goes for cleaning. ventilation pipes. For this purpose, specialized high-power blowing units are used.